HYDRAULIC / TRANSMISSION OILS
Applications:
- HYDRAULIC APPLICATIONS
- TURBINES
- R&O OR AW TYPE OIL
WEAR GUARD AW
TURBINE FLUID
No. 306
PERFORMANCE CHARACTERISTICS:
• Oxidation resistant (8,000 hours in the ASTM-D943 Oxidation Test)
Oxidation inhibitors and premium quality base oils combine to form a product with outstanding resistance to oxidation and provide the maximum protection against varnish formation at both high and low temperatures. This feature will extend drain intervals.
• Provides excellent anti-wear protection
Special anti-wear, extreme pressure and friction reducing additives provide the highest level of protection against wear and scuffing.
• Friction reduction
Exclusive friction reducing additives provide reduced operating temperature and reduced horsepower requirements in comparison to conventional oils.
• Superior rust protection
Inhibitors protect both steel and yellow metal surfaces against rust and corrosion.
• Demulsibility
Designed to separate rapidly from water.
• High foam resistance
Foam inhibitors provide a high level of foam resistance to prevent pump starvation and damage.
• High viscosity index
To insure viscosity stability
• Superior filterability
Oxidation inhibitors and premium quality base oils combine to form a product with outstanding resistance to oxidation and provide the maximum protection against varnish formation at both high and low temperatures. This feature will extend drain intervals.
• Provides excellent anti-wear protection
Special anti-wear, extreme pressure and friction reducing additives provide the highest level of protection against wear and scuffing.
• Friction reduction
Exclusive friction reducing additives provide reduced operating temperature and reduced horsepower requirements in comparison to conventional oils.
• Superior rust protection
Inhibitors protect both steel and yellow metal surfaces against rust and corrosion.
• Demulsibility
Designed to separate rapidly from water.
• High foam resistance
Foam inhibitors provide a high level of foam resistance to prevent pump starvation and damage.
• High viscosity index
To insure viscosity stability
• Superior filterability
SERVICE APPLICATIONS:
Wear Guard AW Hydraulic Oil meets and exceeds the following service requirements for hydraulic pumps:
Vickers 1-286-S, M-2950-S
Denison HF-1, HF-2, HF-0
Cincinnati Milacron P-68, P-69, P-70
General Motors LH-04-1, LH-06-01, LH-15-1
Lee Norse 100-1
Jeffrey No. 87
Ford M-6C32
U.S. Steel 127, 136
B.F. Goodrich 0152
Commercial Shearing
TYPICAL SPECIFICATIONS:
Oxidation Stability,
TOST, ASTM D943, hr 1 8,000+
ASTM 2266 Four Ball Wear Test
40 KG, 1 hour @ 167° F Scar 0.30
Corrosion test, Steel,
(ASTM D665) Procedure B: Pass
Foam Test ASTM D-892
Available foam after 10 min. Nil
Rust Test ASTM D-665 A/B
Distilled Water Pass-clean
Synthetic Sea Water Pass-clean
Demulsibility Test ASTM D-1401 Pass
Denison Filterability
TP 02100
A. No Water (sec.) 600 max. 94/97
B. 2% water (sec.)2 x A max. 149/148